Mag-ARFI: Magnitude-Based MR Acoustic Radiation Force Imaging

This technology enables faster, more accurate MRI imaging of tissue displacement caused by focused ultrasound, using a new method that encodes movement as changes in image brightness instead of phase, reducing motion artifacts and improving real-time guidance for ultrasound therapies.

Background

Transcranial ultrasound stimulation (TUS) is a rapidly growing therapeutic modality for treating anxiety, pain, and depression due to its ability to provide millimeter-level focus deep within the brain. Unlike thermal therapies, TUS does not increase tissue temperature, rendering traditional MR-thermometry ineffective for monitoring. Consequently, Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI) has emerged as the gold standard for visualizing the minute tissue displacements (as small as 1 micron) caused by ultrasound.

However, traditional MR-ARFI relies on phase-contrast imaging, which encodes displacement as a phase shift. This approach requires multiple phase-reference images to subtract background noise, significantly increasing scan times and increasing susceptibility to motion artifacts from a patient’s heartbeat or respiration. Furthermore, these methods often require long echo times that reduce the signal-to-noise ratio (SNR) and complicates clinical workflows.

Technology

This technology, Mag-ARFI, overcomes these limitations by converting ultrasound-induced phase shifts into changes in longitudinal magnetization. By using a specialized magnetization preparation sequence, typically involving 90°, 180°, and -90° pulses, displacement is encoded directly into the magnitude (brightness) of the MR image rather than the phase. This fundamental shift eliminates the need for phase subtraction and reference scans, drastically reducing scan complexity and sensitivity to physiological motion.

Mag-ARFI is designed for high-efficiency clinical use, allowing for high-SNR readouts (such as TSE, EPI, or RAGE) that can acquire multiple lines of k-space for every single ultrasound pulse. The sequence can be tuned to show the ultrasound focus alone or a self-registered image of the focus overlaid on the background anatomy, ensuring precise targeting without the risk of misregistration. This positioning makes Mag-ARFI a vital advancement for the safe and effective guidance of non-invasive brain stimulation and other focused ultrasound therapies.

Benefits

  • Reduced scan time through elimination of phase subtraction
  • Fewer motion artifacts in images
  • Improved safety and effectiveness for guiding focused ultrasound therapies, especially in sensitive applications like brain neuromodulation

Applications

  • Guided focused ultrasound brain therapy
  • Real-time ultrasound neuromodulation monitoring
  • Non-invasive tissue displacement imaging
  • MR-guided ultrasound tumor ablation
  • Motion-robust musculoskeletal imaging

Additional info

Case Western Reserve University is seeking a strategic partner to license or co-develop this magnitude-based encoding platform, which offers a turnkey solution for manufacturers of MR-guided focused ultrasound systems. By integrating this technology, licensees can provide clinicians with a more robust, motion-insensitive imaging suite that reduces total procedure time and enhances targeting accuracy for neurological and body-based ultrasound therapies. This represents a high-value opportunity to differentiate product offerings in the rapidly expanding field of non-invasive neuromodulation.

PCT Application Pending (PCT/US2025/011433)

CWRU-4276